During programming of a straight line, both positions of the active plane and an angle were specified (the position of
the end point is over-specified), or the position of the programmed coordinate cannot be reached with the specified
angle. If a contour consisting of two straight lines is to be programmed with angles, it is possible to specify the two axis
positions of the plane and an angle in the second block. The error can also occur if, due to a programming error, the
preceding block cannot be interpreted as the first subblock of such a contour. A block is interpreted as the first block
of a two-block contour if an angle, but not an axis of the active plane, was programmed, and if the block is not already
the second block of a contour.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10800
[Channel %1: ] Block %3 axis %2 is not a geometry axis
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
Definitions:
With an active transformation or a frame with a rotation component the geometry axes are needed for block
preparation. If a geometry axis has previously been traversed as positioning axis, it retains its status of "positioning
axis" until it is again programmed as a geometry axis.
Because of the POSA motion beyond block boundaries, it is not possible to identify in the preprocessing run whether
the axis has already reached its target position when the block is executed. This is, however, an unconditional
requirement for calculating the ROT component of the frame or of the transformation.
If geometry axes are used as positioning axes, then:
1. No rotation may be specified in the current overall frame.
2. No transformation may be selected.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
After selecting transformation or frame, reprogram the geometry axis now operating as positioning axis (e.g. with
WAITP) in order to revert the status to "geometry axis.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10805
[Channel %1: ] Block %2 repositioning after switch of geometry axes or transformation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the asynchronous subroutine the assignment of geometry axes to channel axes was changed or the active
transformation modified.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10810
[Channel %1: ] Block %2 master spindle not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The function "Revolutional feedrate" (with G95 or G96), or "Rigid tapping" (with G331/G332) has been programmed,
although no master spindle is defined from which the speed could be derived.
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
123

Advertisement

Table of Contents
loading

Table of Contents