Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 229

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

16420
[Channel %1: ] Block %2 axis %3 programmed repeatedly
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
It is not allowed to program an axis more than once.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Delete the axis addresses that have been programmed more than once.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16430
[Channel %1: ] Block %2 geometry axis %3 cannot traverse as positioning axis in
rotated coordinate system
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In the rotated coordinate system, traversing of a geometry axis as positioning axis (i.e. along its axis vector in the
rotated coordinate system) would mean traversing of several machine axes. This is in conflict with the positioning axis
concept, however, in which one axis interpolator runs in addition to the path interpolator!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Traverse geometry axes as positioning axes only with rotation deactivated.
Deactivate rotation:
Keyword ROT without further specification of axis and angle.
Example: N100 ROT
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16440
[Channel %1: ] Block %2 rotation programmed for non-existent geometry axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A rotation of a geometry axis which does not exist was programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16500
[Channel %1: ] Block %2 chamfer or rounding negative
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A negative chamfer or rounding has been programmed under the keywords CHF= ..., RND=... or RNDM=...
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Values for chamfers, roundings and modal roundings must be programmed with positive values only.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
229

Advertisement

Table of Contents
loading

Table of Contents