SINUMERIK 808D ADVANCED alarms
3.3 Drive alarms
Remedy:
- Please inform the authorized personnel/service department.
- Create more space in the file system. It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of
memory. If these remedies do not work, it will be necessary to increase the number of files per directory or the size of
the file system itself (this will require a complete data backup).
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18321 $MM_MAXNUM_SYSTEM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR,
- 18310 $MM_NUM_DIR_IN_FILESYSTEM,
- Power On
- Reload saved data
- On error code 1 == 291: Replace the drive software and use version with suitable ACC basic information.
- On error code 1 == 292: Replace the drive software and use fewer different versions of the drive software.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
300412
Error when storing a file (%1, %2)
Parameters:
%1 = Error code 1
%2 = Error code 2
Definitions:
An attempt to save a data block, e.g. the result of a measuring function, in the file system has failed.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Create more space in the file system. It is normally
sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory. If these remedies do not work, it will be necessary
to increase the number of files per directory or the size of the file system itself. To do so, proceed as follows:
- Save all data
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18321 $MM_MAXNUM_SYSTEM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR
- 18310 $MM_NUM_DIR_IN_FILESYSTEM
- Power On
- Reload saved data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
300423
Measuring result could not be read (%1)
Parameters:
%1 = Error code
Definitions:
An attempt to read a measurement result has failed:
- Error code = 4: Not enough space for test result
- Error code = 16: Measurement not yet finished
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Repeat measurement. Alter measuring time if necessary.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
380001
PROFIBUS/PROFINET: Startup error, reason %1 parameter %2 %3 %4.
Parameters:
%1 = Cause of the error
%2 = Parameter 1
%3 = Parameter 2
%4 = Parameter 3