SINUMERIK 808D ADVANCED alarms
3.5 Cycle alarms
Definitions:
Remedy:
- Check configuration/parameterization of the spindle axis
- If the intention to use a 3D workpiece probe at a "non-SPOS capable spindle",
then check the setting of MD 52207 $MCS_AXIS_USAGE_ATTRIB[n], bit 9 (also see Commissioning instructions,
cycles)
- If a 3D workpiece probe is attached to the machine outside the spindle,
then check the setting of MD 51740 $MNS_MEA_FUNCTION_MASK, bit 4. (also see Commissioning instructions,
cycles)
61374
[Channel %1: ] Block %2: Probe not calibrated in axis direction %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Calibrate the probe in the specified axis direction.
61375
[Channel %1: ] Block %2: Trigger values of measuring sensor are incompatible
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Trigger values of the tool measuring sensor must be fully described either via the _TP[] / _TPW[] fields or via the setting
data
(SD: 54625-54632 or SD: 54640-54647). A mixture of the two variants is not permitted.
61376
[Channel %1: ] Block %2: Number of teeth missing from tool parameters
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Enter number of teeth of the tool in the tool management
61377
[Channel %1: ] Block %2: Dimensional tolerance %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
61378
[Channel %1: ] Block %2: Tool spindle is not the master spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Before calling the measuring cycles, the tool spindle must be defined as master spindle (SETMS...).
61379
[Channel %1: ] Block %2: Too many teeth
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
As a result of the cycle, tools with a maximum of 100 teeth can be measured.
61380
[Channel %1: ] Block %2: Tool probe width too small
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions: