3.2 NCK alarms
10792
[Channel %1: ] Block %2 illegal interpolation type during linear programming with
angles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only spline or linear interpolation is permitted for programming two straight lines with angle specification. Circular or
polynomial interpolation is not allowed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10793
[Channel %1: ] Block %2 second block missing during linear programming with angles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The second block is missing during programming of two straight lines with angle specification. This situation only
occurs if the first subblock is also the last block of a program, or if the first subblock is followed by a block with a
preprocessor stop.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10794
[Channel %1: ] Block %2 angle specification missing in 2nd block during linear
interpolation with angles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The angle is missing from the second block during programming of two straight lines with angle specification. This
error can only occur if an angle was programmed in the preceding block, but no axis of the active plane was
programmed in that block. The cause of the error may therefore also have been the intention to program a single
straight line with an angle in the previous block. In this case, exactly one axis of the active plane must be programmed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10795
[Channel %1: ] Block %2 end point specification during angle programming
contradictory
Parameters:
%1 = Channel number
%2 = Block number, label
122