Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 186

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of initialization values.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14140
[Channel %1: ] Block %2 position programming without transformation not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Position information was programmed for an axis position but no transformation was active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14144
[Channel %1: ] Block %2 PTP movement not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The PTP G code was programmed for a movement other than G0 or G1.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14146
[Channel %1: ] Block %2 CP or PTP movement without transformation not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The CP or PTP G code was programmed for a movement but no transformation was active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14157
[Channel %1: ] Block %2 illegal interpolation type with MOVT
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Linear or spline interpolation must be active with MOVT (G0, G1, ASPLINE, BSPLINE, CSPLINE).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
186
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual

Advertisement

Table of Contents
loading

Table of Contents