SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Remedy:
- Modify part program.
- If new cycle programs have been loaded on the NCK, you will normally need to increase the values of MD18170
$MN_MM_NUM_MAX_FUNC_NAMES and MD18180 $MN_MM_NUM_MAX_FUNC_PARAM. See also the
explanations for alarm 6010.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15176
[Channel %1: ] Block %2 Program%3 may only be executed after Power ON
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
Definitions:
If an encrypted program is loaded to the NCK, an NCK reset (restart) must be performed afterwards, because internal
data for efficient processing of the encrypted program are preprocessed during NCK power-up. On calling an
encrypted NC program it has now been detected that these data do not exist or are obsolete compared to the current
version of the encrypted NC program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Perform an NCK reset (restart).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15177
[Channel %1: ] Block %2 Error on preprocessing of program %3, error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
%4 = Error code
Definitions:
If an encrypted program is loaded to the NCK, an NCK reset (restart) must be performed afterwards, because internal
data for efficient processing of the encrypted program are preprocessed during NCK power-up. The following problem
has occurred:
Error code 1: Error on read-in of program %4
Error code 2: There is not enough DRAM memory available for storing the preprocessed data.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Error code 1: Encrypt and load program %4 again. Then perform an NCK reset (restart).
Error code 2: Increase system SL 710-740, 802D, 828D: $MN_MM_T_FILE_MEM_SIZE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15179
Error when copying the file 'restorafs.inm', error ID %1
Parameters:
%1 = Error code
%2 = Is not used
%3 = Is not used
Definitions:
Copying the file 'restoreafs.inm' from the CF card into the active file system (to /_N_SYF_DIR) failed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The restore file 'restoreafs.inm' was not executed. The file lies on the CF Card under /siemens/sinumerik/sys_cach/
nck/
Remedy: Copy 'restoreafs.inm' via HMI to /_N_SYF_DIR/_N_RESTOREAFS_INM before the next restart, and then
delete or rename the file on the CF card to prevent the restore file being executed at every restart.
216
Increase system SL 840 DI: $MN_MM_DRAM_FILE_MEM_SIZE.
Then perform an NCK reset (restart).
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1