Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 397

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

61414
[Channel %1: ] Block %2 : distortion of triangle over limit
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check the setpoint and actual values
61415
[Channel %1: ] Block %2: Check probe / machining plane
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Enter permissible probe for machining plane:
- For 840D sl - up to SW 1.x: Check the variables _TP[x,8] and _TPW[x,8] in GUD6
- For 840D sl/828D - as from SW 2.5: Check the setting data 54633 $SNS_MEA_TP_TYPE and/or 54648
$SNS_MEA_TPW_TYPE
or change the machining plane.
61416
[Channel %1: ] Block %2: Probe number is greater than the maximum number of fields
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check parameter S_PRNUM
Measure workpiece: Parameter S_PRNUM 1 to 12
Measure tool: Parameter S_PRNUM 1 to 6
61417
[Channel %1: ] Block %2: Probe will collide with the carrier of the reference groove.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Take up collision-free initial position of the axes involved in the measuring process.
61418
[Channel %1: ] Block %2: Protocol file too small, check MD11420:
LEN_PROTOCOL_FILE.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check MD11420: LEN_PROTOCOL_FILE.
61419
[Channel %1: ] Block %2: Check probe calibration with reference to center of ball/
circumference of ball.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Setting in MD 51740 $MNS_MEA_FUNCTION_MASK bit1 does not match calibration status in
setting data 54610 $SNS_MEA_WP_STATUS_GEN[S_PRNUM] - THOUSANDS digit: 1=circumference 0=TCP (Tool
Center Point)
Remedy:
Check machine data 51740 $MNS_MEA_FUNCTION_MASK bit1
Remedy:
1. Recalibrate probe (adjust)
2. Change probe number S_PRNUM
3. Adjust MD51740 bit1