SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
3Tool length offset components have been programmed in one block with both TOFF and TOFFL.
4An index must be declared when a tool length offset is programmed with TOFF, the form TOFF=.... is not permissible.
5An illegal index was declared when programming TOFFL (permissible values 1..3).
6An illegal axis was declared as the index when programming TOFF. Only geometry axes are permitted.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct errors in program block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14170
[Channel %1: ] Block %2 illegal interpolation type with tool length compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If tool compensation (G43/G44) is activated in language mode ISO_M, the linear type of interpolation must be active.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14180
[Channel %1: ] Block %2 H number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = H number of ISO mode
Definitions:
The specified H number is not assigned to a tool (ISO_M).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14185
[Channel %1: ] Block %2 D number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = D number of ISO mode
Definitions:
The specified D number is not assigned to a tool (language mode ISO_M).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14197
[Channel %1: ] Block %2 D number and H number programmed simultaneously
Parameters:
%1 = Channel number
%2 = Block number, label
188
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual