Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 188

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
3Tool length offset components have been programmed in one block with both TOFF and TOFFL.
4An index must be declared when a tool length offset is programmed with TOFF, the form TOFF=.... is not permissible.
5An illegal index was declared when programming TOFFL (permissible values 1..3).
6An illegal axis was declared as the index when programming TOFF. Only geometry axes are permitted.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct errors in program block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14170
[Channel %1: ] Block %2 illegal interpolation type with tool length compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If tool compensation (G43/G44) is activated in language mode ISO_M, the linear type of interpolation must be active.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14180
[Channel %1: ] Block %2 H number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = H number of ISO mode
Definitions:
The specified H number is not assigned to a tool (ISO_M).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14185
[Channel %1: ] Block %2 D number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = D number of ISO mode
Definitions:
The specified D number is not assigned to a tool (language mode ISO_M).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14197
[Channel %1: ] Block %2 D number and H number programmed simultaneously
Parameters:
%1 = Channel number
%2 = Block number, label
188
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual

Advertisement

Table of Contents
loading

Table of Contents