SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
12571
[Channel %1: ] Block %2 %3 not permissible for motion synchronous action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The predefined subprogram %3 specified here is not allowed in a block with motion synchronous action. It may only
be contained in a "normal" block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12572
[Channel %1: ] Block %2 %3 only permissible for motion synchronous action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The predefined subprogram %3 specified here is only allowed in a block with motion synchronous action. It must not
be contained alone in a "normal" block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12573
[Channel %1: ] Block %2 motion-synchronous action: Call by reference parameters not
allowed %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source text area
Definitions:
Call by reference parameters (keyword VAR) are not possible with technology cycles.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct PROC instruction of technology cycle.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12580
[Channel %1: ] Block %2 %3 not permissible for assignment in motion synchronous
action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The variable displayed must not be written in a motion synchronous action. Only selected variables are permitted here,
e.g. DO $AA_IW[X]=10 is not allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Modify part program.
In a motion synchronous action, only certain variables are allowed.
E.g. $AA_IM, $AC_DTGPB
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
158