Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 335

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Definitions:
An error occurred during startup of the PROFIBUS/PROFINET master.
Overview: Cause of the error, Par 1, Par 2, Par 3:
- 01 = DPM version, DPM version, DPA version, --
- 02 = DPM ramp-up timeout, DPM actual value status, DPM setpoint value status, --
- 03 = DPM ramp-up status, DPM actual value status, DPM setpoint value status, DPM error code
- 04 = DPM ramp-up error, DPM actual value status, DPM setpoint value status, DPM error code
- 05 = DPM-PLL sync error, --, --, --
- 07 = Alarm queue too long, Actual number, Setpoint number, --
- 08 = Unknown client, Client ID, --, --
- 09 = Client version, Client ID, Client version, DPA version
- 10 = Too many clients, Client number, max. number of clients, --
- 11 = Log.basic address used several times; bus no.; slot no.; log.basic address --
- 20 = Slave/device address used several times, slave/device address --
- 21 = Slave/device address unknown, slave/device address, --
- 22 = Erroneous configuration telegram, slave/device address, error code, --
- 23 = OMI incompatible (data), drive version, CDA version, --, --
- 24 = OMI incompatible (driver), drive version, CDA version, --, --
- 25 = CPI initialization failed, error code, --, --, --
- 26 = DMA not active
- 27 = Reserved
- 28 = Reserved
- 29 = Reserved
- The 1000s digit of the error cause = number of the affected bus
- (Special case: Error causes in the 5000 range indicate problems with the NCU-LINK communication)
Clients are the following components of the control system that use the PROFIBUS/PROFINET:
Client ID = 1: PLC
Client ID = 2: NCK
Possible causes are:
- Error in contents of SDB
- Corruption of parts of the system program
- Hardware defect on NC component
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy for 1-11
1. Check the control project, check MD11240 $MN_PROFIBUS_SDB_NUMBER, and reload it when using a user-
specific SDB.
2. If the error still occurs, back up data, and restart the control with the standard values as per the as-delivered
condition.
3. In case of correct ramp-up, reload the user data stage by stage.
4. If the error still occurs during ramp-up with standard values, reboot the system from the PC card or update the
software.
5. If the error still occurs, replace the hardware.
Remedy for 20-21
1. Check/correct the addresses of the connected slaves/devices.
Remedy for 22
See SINAMICS warning 1903 for a description of the meaning behind the error codes.
1. Control the SDB
- Check the type and length of the message frame
- Match slot assignment with P978
2. Evaluate the drive alarms/warnings
Remedy for 23-24
1. Software replacement required
Remedy for 25
1. Change the message frame type
2. Reduce the number of slots
3. Reduce the number of slaves/devices
4. Create a new SDB
5. Software must be replaced
If the error has still not been able to be rectified after this procedure, send the error text to the control manufacturer.
Program
Switch control OFF - ON.
Continuation:
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.3 Drive alarms
335

Advertisement

Table of Contents
loading

Table of Contents