Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 201

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

14712
[Channel %1: ] Error selecting JOG Retract: error code %4 info %3
Parameters:
%1 = Channel number
%2 = Is not used
%3 = Additional information
%4 = Error code
Definitions:
An error occurred on the selection of JOG Retract, which is described in more detail by the error code (parameter%4):
List of error codes:
1: No retract data available
2: Selection is active during taper turning
3: Error preparing the initialization blocks. The additional info (parameter %3) states the initialization step in which the
error occurred. The alarm output immediately before also refers to this initialization step:
100: Error synchronizing the preprocessing/main run
101: Error selecting the tool length compensation
102: Error selecting the transformation
103: Error generating the tool frame
104: Error generating the tapping block
105: Error replacing geometry axes
4: The position of the axis stated in the additional info does not have the status "synchronized" or "restored"
5: The axis stated in the additional info is already assigned in another channel by JOG Retract
6: The geometry axis stated by the selection of JOG Retract does not exist
7: MD 20110 $MC_RESET_MODE_MASK bit 0 is not set
8: Thread cutting is active. The thread direction cannot be explicitly assigned to a JOG axis
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The following conditions have to be fulfilled in order to select JOG Retract:
- A program execution with active tool offset has been canceled by Reset or PowerOff
- PLC signal DB3300.DBX4005.5 (Retract data available) or OPI variable retractState bit 1 is set
- JOG mode is active
- The channel in which JOG Retract is to be selected is in Reset state
- The function "Taper turning" must not be active when JOG Retract is selected
- Synchronized or restored axis positions must be present for the axes involved in the transformation
If necessary, activate position restoration for incremental encoders (MD34210 $MA_ENC_REFP_STATE[]=3)
- MD 20110 $MC_RESET_MODE_MASK bit 0 must be set (default value)
In the case of an error, the alarm must be acknowledged with Reset. The selection can then be repeated, observing
the above-mentioned conditions.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14750
[Channel %1: ] Block %2 too many auxiliary functions programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
More than 10 auxiliary functions have been programmed in an NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check whether all auxiliary functions are necessary in one block - modal functions need not be repeated. Create
separate auxiliary function block or divide the auxiliary functions over several blocks.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14751
[Channel %1: ] Block %2 resources for motion synchronous actions not sufficient
(code: %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
201

Advertisement

Table of Contents
loading

Table of Contents