3.2 NCK alarms
15950
[Channel %1: ] Block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure with deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command MEAS (measure
with deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
15960
[Channel %1: ] Block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure without deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command MEAW (measure
without deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16000
[Channel %1: ] Block %2 invalid value for lifting direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During the "rapid lift from contour" (keyword: LIFTFAST), a code value for the lifting direction (keyword: ALF=...) which
lies outside the permissible range (permissible value range: 0 to 8) was programmed .
With active cutter radius compensation:
Code numbers 2, 3 and 4 cannot be used in G41
Code numbers 6, 7 and 8 cannot be used in G42 because they code the direction to the contour.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program the lifting direction under ALF=... within the permissible limits.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16005
[Channel %1: ] Block %2 invalid value for lifting distance
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Mistake in programming: the value for the lifting path must not be negative.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: