Remedy:
Please inform the authorized personnel/service department.
- Purchase option
- Reset the activation of 'Advanced Surface' functionality (MD20606 $MC_PREPDYN_SMOOTHING_ON and/or
MD20443 $MC_LOOKAH_FFORM)
Program
Switch control OFF - ON.
Continuation:
8030
[Channel %1: ] Block %2 option 'interpolation of more than %3 axes' not set
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of permissible axes
Definitions:
The option for the number of interpolating axes does not correspond to the number of axes programmed in the
interpolation group.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Option: "Interpolation of more than 4 axes" (the number of axes permitted can be set in this option) or, in the part
program, program up to as many axes as are permitted by the configuration of the controller.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8031
[Channel %1: ] Block %2 axis %3: Axis has no IPO functionality
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle number
Definitions:
An axis/spindle that has been defined as a special axis/auxiliary spindle (see MD30460
$MA_BASE_FUNCTION_MASK bit8), should be operated as an interpolating axis.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define axis as interpolating axis (see MD30460 $MA_BASE_FUNCTION_MASK bit8) or change part program
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8037
'Activate APC/Number of current setpoint filters' option not set.
Definitions:
More than six current setpoint filters were activated in the drive, although the corresponding option had not been set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Buy option
- Deactivate the 'Advanced Positioning Control' (APC) function in the drive.
- Set a maximum of six current setpoint filters in the drive.
Program
Switch control OFF - ON.
Continuation:
8040
Machine data %1 reset, corresponding option is not set
Parameters:
%1 = String: MD identifier
Definitions:
A machine data has been set that is locked by an option.
Reaction:
Alarm display.
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms