SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
17181
[Channel %1: ] Block %2 T no.= %3, D no.= %4 not existing
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions:
A programmed D number was not recognized by the NC. By default, the D number refers to the specified T number.
If the flat D number function is active, T= 1 is output.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
If the program is incorrect, remedy the error with a correction block and continue the program.
If the data block is missing, download a data block for the specified T/D values onto the NCK (via HMI with overstore)
and continue the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17183
[Channel %1: ] Block %2 H number already available in T no.= %3, D no.= %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions:
Each H number (except for H=0) must be assigned in a TO unit only once. The indicated edge already has the H
number. If the H number shall be assigned more than once, MD10890 $MN_EXTERN_TOOLPROG_MODE, bit 3
must be set = 1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Change program:
- Select different H number
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17188
[Channel %1: ] D number %2 defined in tool T no. %3 and %4
Parameters:
%1 = Channel number
%2 = Offset number D
%3 = T number of first tool
%4 = T number of second tool
Definitions:
The specified D number %2 in the TO unit of channel %1 is not unique. The specified T numbers %3 and %4 each
have an offset with number %2. If tool management is active: The specified T numbers belong to tool groups with
different names.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
1. Ensure that the D numbers within the TO unit are unique.
2. If unique numbering is not necessary for subsequent operations, do not use the command.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17190
[Channel %1: ] Block %2 illegal T number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
Definitions:
In the displayed block, access is made to a tool that is not defined and therefore not available. The tool has been
named by its T number, its name or its name and duplo number.
Reaction:
Correction block is reorganized.
Interface signals are set.