SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
10915
[Channel %1: ] Block %2 Preparation problem in LookAhead (Identifier %3, Details %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
%4 = Error details
Definitions:
The NCK was incorrectly parameterized (under certain circumstances, the parameterized memory is not sufficient),
which is why LookAhead can no longer be operated in the expansion mode.
Reaction:
Interpreter stop
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change parameterization (increase LookAhead memory and/or IPO buffer, change tolerances). Use standard
LookAhead.
Contact Siemens if necessary.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10916
[Channel %1: ] Block %2 Preparation problem in LookAhead (Identifier %3, Details %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
%4 = Error details
Definitions:
The NCK was incorrectly parameterized (under certain circumstances the parameterized memory is not sufficient),
this is the reason that the generated profile is not as smooth and uniform as it could be.
Reaction:
Local alarm reaction.
Alarm display.
Warning display.
Remedy:
Change the parameterization (increase the LookAhead memory and/or IPO buffer, change tolerances).
1010: Increase IPO buffer to at least 50 blocks, or maximum number of blocks in the braking ramp times 2.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10930
[Channel %1: ] Block %2 interpolation type not allowed in stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following types of interpolation are allowed in the contour program for stock removal: G00, G01, G02, G03, CIP,
CT
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the contour subroutine, program only path elements that consist of straight lines and arcs.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10931
[Channel %1: ] Block %2 incorrect stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following errors occurred in the subroutine for the contour during stock removal:
- Full circle
- Overlapping contour elements
- Wrong start position
Reaction:
Local alarm reaction.
130