- If the alarm occurs while writing one of the parameters $TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether machine data MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC /
MD18076$MN_MM_NUM_LOCS_WITH_DISTANCE has been set correctly.
MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 statements that may
be made for an Index2 value.
MD18076 $MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer locations that may be
named in Index2.
If a multitool is to be generated or its locations, the alarm indicates that either more multitools need to be generated
than are permitted by the setting of MD18083 $MN_MM_NUM_MULTITOOL or, if the alarm occurs when the multitool
locations are being generated, that more multitool locations need to be generated than is permitted by the setting of
MD18085 $MN_MM_NUM_MULTITOOL_LOCATIONS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify machine data
- Modify NC program, i.e. reduce number of rejected variable.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17010
[Channel %1: ] Block %2 no memory left
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When executing/reading files from the active working memory, it was found that there is not enough memory space
(e.g. for large multidimensional arrays or when creating tool offset memory).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Make arrays smaller or make more memory space
available for memory management of subroutine calls, tool offsets and user variables (machine data MM_...).
See /FB/, S7 Memory Configuration
Program
Clear alarm with the RESET key. Restart part program
Continuation:
17018
[Channel %1: ] Block %2 incorrect value for parameter %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Parameter name
Definitions:
An incorrect value has been assigned to the stated parameter.
Only the following values are permissible for the parameter $P_WORKAREA_CS_COORD_SYSTEM
=1 for workpiece coordinate system
=3 for settable zero system.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Assign another value.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
17020
[Channel %1: ] Block %2 illegal array index 1
Parameters:
%1 = Channel number
%2 = Block number, label
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
253