4180
Invalid M function number assigned to enable ASUP
Definitions:
An invalid M function number has been assigned for activation of ASUP. An illegal M number has been assigned in
MD10804 $MN_EXTERN_M_NO_SET_INT or MD10806 $MN_EXTERN_M_NO_DISABLE_INT for the configuration
of the M number range for activation/deactivation of the interrupt program.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check MD10804 $MN_EXTERN_M_NO_SET_INT and MD10806 $MN_EXTERN_M_NO_DISABLE_INT.
Program
Switch control OFF - ON.
Continuation:
4181
[Channel %1: ] Invalid assignment of an M auxiliary function number
Parameters:
%1 = Channel number
Definitions:
In MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256 $MC_AUXFU_ASSOC_M1_VALUE, a number has
been specified for the configuration of a new predefined M function which is occupied by the system, and cannot be
used for an assignment. (M0 to M5, M17, M30, M40 to M45).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in machine data MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17, M30, M40 to M45).
Program
Switch control OFF - ON.
Continuation:
4182
[Channel %1: ] Invalid M auxiliary function number in %2%3, MD reset
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index
Definitions:
In the specified machine data, a number has been specified for the configuration of an M function which is occupied
by the system, and cannot be used for an assignment. (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with
applied ISO dialect). The value set by the user has been reset to the default value by the system.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in the specified machine data which is not occupied by the system (M0 to M5, M17, M30, M40
to M45 and also M98, M99 with applied ISO dialect).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4183
[Channel %1: ] M auxiliary function number %2 used several times (%3 and %4)
Parameters:
%1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
Definitions:
In the specified machine data, a number has been used several times for the configuration of an M function.
Reaction:
Mode group not ready.
Channel not ready.
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
69