SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Remedy:
Please inform the authorized personnel/service department. Do not use rapid interrupt inputs or contact the machine
manufacturer with a view to retrofitting this option!
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8010
Option 'activation of more than %1 axes' not set
Parameters:
%1 = Number of axes
Definitions:
More machine axes have been defined through the MD20070 $MC_AXCONF_MACHAX_USED than are allowed in
the system.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. The sum of all axes that have been configured using the
channel-specific MD20070 $MC_AXCONF_MACHAX_USED must not exceed the maximum number of axes
(dependent upon the configuration -> option, basic version: 4 axes).
Please also observe the information relating to the definition of auxiliary axes/spindles.
Program
Switch control OFF - ON.
Continuation:
8012
The 'Activation of more than %1 SI axes' option is not set
Parameters:
%1 = Number of licensed axes
%2 = Number of axes with active dbSi
Definitions:
The drive-based safety functions were activated for more axes than permitted in the system.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please notify the authorized personnel / service department. Reduce the number of axes activated with drive-based
safety functions or release additional axes in the option date.
Program
Switch control OFF - ON.
Continuation:
8022
Option 'activation of more than %1KB SRAM' not set
Parameters:
%1 = Memory size
Definitions:
The option for memory extension does not correspond to the active SRAM.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Buy option
- Activate less SRAM
Program
Switch control OFF - ON.
Continuation:
8025
[Channel %1: ] Option 'Advanced Surface' not set
Parameters:
%1 = Channel number
Definitions:
The option for 'Advanced Surface' functionality is not set.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.