Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14700
[Channel %1: ] Block %2 timeout during command to interpreter
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A timeout has occurred in control-internal commands such as ANWAHL (part program selection), RESET (channel
reset), REORG (reorganization of the preprocessing buffer) and NEWCONFIG (change in the configuration-specific
machine data = restart).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
If the runtime error occurred as the result of a temporary excessive load on the system (e.g. in the HMI area or in OEM
applications) error-free execution is possible on repeating the program or operator action.
Otherwise, place a support request with the error text under: http://www.siemens.com/automation/support-request
Program
Switch control OFF - ON.
Continuation:
14701
[Channel %1: ] Block %2 number of available NC blocks reduced by %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of non-available blocks
Definitions:
After reset, it has been found that the number of available blocks has decreased compared with the last reset. This is
due to a system error. Part program execution can be resumed after the alarm has been acknowledged. If the number
of blocks no longer available is less than MD28060 $MC_MM_IPO_BUFFER_SIZE, then the POWERON alarm 14700
is output.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Proceed as in the case of a system error.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14710
[Channel %1: ] Block %2 error in initialization sequence in function %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier of the function which caused the error
Definitions:
Initialization blocks are generated (or not) after control power-up, (program) RESET and (program) START, depending
on the settings in machine data MD20110 $MC_RESET_MODE_MASK and MD20112 $MC_START_MODE_MASK.
Errors can occur because of incorrect machine data settings. The errors are output with the same error messages as
would appear if the function had been incorrectly programmed in the part program.
This alarm is also generated in order to indicate that an error relates to the initialization sequence.
Parameter %3 specifies which function triggers the alarm:
Control power-up and (program) RESET:
Value:
0: Error during synchronization preprocessing/main run
1: Error on selection of tool length compensation
2: Error on selection of transformation
3: Error on selection of work offset
The macro definitions and cycle interfaces are also read in during the power-up procedure. If an error occurs here, this
is indicated by value = 4, or value = 5
6: Error creating 2 1/2 D protection areas during power up.
(Program) START:
Value
100: Error during synchronization preprocessing/main run
Diagnostics Manual