Definitions:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Check the value in the parameter advance angle _INCA!
- If 3-point measurement is selected, _INCA must not be greater/less than +/-120°, and with 4-point measurement
_INCA must not be greater/less than +/-90°.
- The advance angle _INCA must always be parameterized unequal to "zero".
For 840D sl - aa from SW 2.7 and for 828D - as from SW 4.4:
- Check the value in the parameter advance angle alpha 1!
- If 3-point measurement is selected, alpha 1 must not be greater/less than +/-120° and with 4-point measurement,
alpha 1 must not be greater/less than +/-90°!
- The advance angle alpha 1 must always be parameterized unequal to "zero".
61444
[Channel %1: ] Block %2: Current measuring speed is not identical to the calibration
speed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
The relevant calibration speed is also stored in each calibration data record.
The current measuring speed with feedrate override of 100% is not equal to the calibration speed.
After calibration, the calibration speed value must be in the following setting data.
For workpiece measurement:
For tool measurement:
Recalibrate probe (adjust) or specify new S_PRNUM.
61445
[Channel %1: ] Block %2: Check holder angle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check the entry for the holder angle in the tool offset.
For cutting edge positions 1-4, the holder angle must be greater than or equal to 90° and less than 180°,
for cutting edge positions 5-8, it must be greater than 0° and less than 90°.
61446
[Channel %1: ] Block %2: Check insert angle and clearance angle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check the entry for the insert angle / clearance angle in the tool offset!
61501
[Channel %1: ] Block %2: Simulation is active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Reset simulation
61502
[Channel %1: ] Block %2: No tool offset active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
A tool number must be programmed
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SD 54611 $SNS_MEA_WP_FEED[S_PRNUM-1] > 0
SD 54636 $SNS_MEA_TP_FEED[S_PRNUM-1] > 0 for calibration in the machine coordinate system
SD 54651 $SNS_MEA_TPW_FEED[S_PRNUM-1] > 0 for calibration in the workpiece coordinate system