When Setting Pr.00-11 To 0, The V/F Control Diagram Is Shown As Follows; When Setting Pr.00-11 To 1, The V/F Control + Encoder Diagram Is Shown As Follows - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

0: (IM V/f control): user can design proportion of V/f as required and can control multiple motors
simultaneously.
1: (IM V/f control + Encoder): user can use optional PG card with encoder for the closed-loop
speed control.
2: (IM Sensorless vector control): get the optimal control by the auto-tuning of motor
parameters.
3: (IM FOC vector control+ encoder): besides torque increases, the speed control will be more
accurate (1:1000).
4: (PM FOC vector control + Encoder): besides torque increases, the speed control will be more
accurate (1:1000).
5: FOC Sensorless: IM field oriented sensorless vector control
6: PM Sensorless (PM field oriented sensorless vector control)
 When setting Pr.00-11 to 0, the V/F control diagram is shown as follows.
Fcmd
Pr00-20
V/F
table
01-00,01-01
01-02,01-03
01-04,01-05
01-06,01-07
01-08
 When setting Pr.00-11 to 1, the V/F control + encoder diagram is shown as follows.
Fcmd
Frequ en cy
00- 20
Ina ccura cy
accel/decel time
DC BUS
Voltage
Detect
Top Limit F:01-10
Lower Limit F:01-11
Vcmd
Filter
Time
07-24
V/F
table
Vol tage
+
Co mman d
X
+
Filter
Time
Fcmd
07-24
Filter Time
Chapter 12 Description of Parameter SettingsC2000 Series
DC BUS Voltage
2/3
AVR
e->s
07-23
Torque
3/2
Compe nsate
s->e
07-26
Frequ en cy
Ina ccura cy
Vol tage Compe nsate
Vol tage
Powe r
cmd
Slip
Factor
com p.
07-26
Real Speed
12-7
Protection
Current Detection
IGBT
M
PWM
01-00
01-01
01-02
05-01
05-02
05-03
05-04
Cu rren t
D etect
IGBT
M
PWM
EN
Irm s
Real Speed