Settings
Functions
st
nd
The 1
, 2
acceleration
8
or deceleration time
selection
rd
th
The 3
, 4
acceleration
9
or deceleration time
selection
EF Input (EF: External
10
fault)
External B.B. Input (Base
11
Block)
Output Stop
12
(Output pause)
Cancel the setting of the
13
optimal accel./decel. time
Switch between drive
14
settings 1 and 2
Operation speed
15
command form AVI
Operation speed
16
command form ACI
Operation speed
17
command form AUI
18
Emergency Stop (07-20)
Chapter 12 Description of Parameter SettingsC2000 Series
Fr eq ue ncy
S etti ng
A ccel . in hi bi t
fr eq ue ncy
a re a
A ccel . in hi bi t
a re a
A ctua l o pe ra tio n fr eq ue ncy
O N
MIx- GND
O pe ra tio n
co mman d
The acceleration/deceleration time of the drive could be selected
from this function or the digital status of the terminals; there are 4
acceleration/deceleration speeds in total for selection.
For external fault input..Motor drive will decelerate by Pr.07-20
setting, keypad will show EF. (it will have fault record when external
fault occurs). Until the causes of fault is eliminated, the drive can
keep running after resetting.
When this contact is ON, output of the drive will be cut off
immediately, and the motor will be free run and keypad will display
B.B. signal. Refer to Pr.07-08 for details.
If this contact is ON, output of the drive will be cut off immediately,
and the motor will then be free run. And once it is turned to OFF,
the drive will accelerate to the setting frequency.
V ol tag e
Fr eq ue ncy
S etti ng
fr eq ue ncy
MI - GND
x
O pe ra tio n
co mman d
Before using this function, Pr.01-44 should be set to 01/02/03/04
first. When this function is enabled, OFF is for auto mode and ON
is for linear accel./decel.
When the contact is ON: use motor 2 parameters.
motor 1 parameters.
When the contact is ON, the source of the frequency will force to be
AVI. (If the operation speed commands are set to AVI, ACI and AUI
at the same time. The priority is AVI>ACI>AUI)
When the contact is ON, the source of the frequency will force to be
ACI. (If the operation speed commands are set to AVI, ACI and AUI
at the same time. The priority is AVI>ACI>AUI)
When this function is enabled, the source of the frequency will
force to be AUI. (If the operation speed commands are set to AVI,
ACI and AUI at the same time. The priority is AVI>ACI>AUI)
When the contact is ON, the drive will ramp to stop by Pr.07-20
setting.
12-36
Descriptions
De cel . in hi bi t
a re a
O N
O N
O N
O FF
O N
O N
A ctua l o pe ra tio n
fr eq ue ncy
De cel . in hi bi t
a re a
Ti me
O N
O FF
Ti me
ON
OFF: use