Canopen Supporting Index; C2000 Index; Delta Standard Mode (Old Definition); Bit3~2 - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

15.4 CANopen Supporting Index

C2000 Index:

Parameter index corresponds to each other as following:
Index
2000H + Group
For example:
Pr.10.15 (Encoder Slip Error Treatment)
Group
10(0
H)
A
Index = 2000H + 0AH = 200A
Sub Index = 0FH + 1H = 10H
C2000 Control Index:

Delta Standard Mode (Old definition)

Index Sub
2020H
0 Number
1 Control word
sub-Index
member+1
member
-
15(0FH)
Factory
Definition
Setting
Chapter 15 CANopen Overview C2000 Series
R/W
Size
3
R
U8
Bit 1~0

Bit3~2

Bit5~4

Bit7~6

Bit11~8
0
RW
U16
Bit12

Bit14~13 00B: no function

15-21
Note
:
00B
disable
:
01B
stop
:
10B
disable
:
11B
JOG Enable
Reserved
:
00B
disable
:
01B
Direction forward
:
10B
Reverse
:
11B
Switch Direction
st
:
00B
1
step Accel. /Decel.
nd
:
01B
2
step Accel. /Decel.
rd
:
10B
3
step Accel. /Decel.
th
:
11B
4
step Accel. /Decel.
0000B: Master speed
st
0001B: 1
step speed
nd
0010B: 2
step speed
rd
0011B: 3
step speed
th
0100B: 4
step speed
th
0101B: 5
step speed
th
0110B: 6
step speed
th
0111B: 7
step speed
th
1000B: 8
step speed
th
1001B: 9
step speed
th
1010B: 10
step speed
th
1011B: 11
step speed
th
1100B: 12
step speed
th
1101B: 13
step speed
th
1110B: 14
step speed
th
1111B: 15
step speed
1: Enable the function of
Bit6-11
01B: Operation command by
the digital keypad

Advertisement

Table of Contents
loading

Table of Contents