20XXH address corresponds to MI MO AI AO.
Slave No. n=0~7
Special D
D2026+100*n MI status of slave No. n
D2027+100*n MO setting of slave No. n
D2028+100*n AI1 status of slave No. n
D2029+100*n AI2 status of slave No. n
D2030+100*n AI3 status of slave No. n
D2031+100*n AO1 status of slave No. n
D2032+100*n AO2 status of slave No. n
D2033+100*n AO3 status of slave No. n
Setting of the PDO mapping length
Special D
D2034+100*n Transmission setting of slave No. n
D2067+100*n Receiving setting of slave No. n

16.5.4 Communication Address for PLC Devices

Device
X
Y
T
M
M
C
D
D
D
Function
Function
Range
00~17 (Octal)
00~17 (Octal)
00~159
000~799
1000~1079
0~79
00~399
1000~1099
2000~2799
Chapter 16 PLC Function C2000 Series
Pre-defined
Setting
0
2026H-0110H
0
2026H-4110H
0
2026H-6110H
0
2026H-6210H
0
2026H-6310H
0
2026H-A110H
0
2026H-A210H
0
2026H-A310H
Pre-defined
Setting
000AH
0000H
Type
bit
bit
bit/word
bit
bit
bit/word
word
word
word
16-32
CAN
PDO
Index
1
2
3
R/W
RW
RW
Address (Hex)
0400~040F
0500~050F
0600~069F
0800~0B1F
0BE8~0C37
0E00~0E47
1000~118F
13E8~144B
17D0~1AEF
R/W
4
RW
RW
RW
RW
RW
RW
RW
RW