When the CNT command is executed from OFFON, which means that the counter
coil is driven, and 1 should thus be added to the counter's value; when the counter
achieved specific set value (value of counter = the setting value), motion of the
contact is as follows:
NO(Normally Open) contact
NC(Normally Close) contact
If there is counting pulse input after counting is attained, the contacts and the counting
values will be unchanged. To re-count or to conduct the CLEAR motion, please use
the RST command.
Example
Ladder diagram:
X0
Mnemonic
Master control Start/Reset

MC/MCR

N0~N7
Operand
1. MC is the main-control start command. When the MC command is executed, the
execution of commands between MC and MCR will not be interrupted. When MC
command is OFF, the motion of the commands that between MC and MCR is
described as follows:
Timer
Accumulative timer
Subroutine timer
Counter
Coils driven up by the OUT
command
Devices driven up by the SET
and RST commands
Application commands
CNT
C2
K100
Command
16-41
Chapter 16 PLC Function C2000 Series
Open
collector
Close
collector
Command code:
LD
CNT
C2 K100
Function
Description
The counting value is set back to zero, the coil and
the contact are both turned OFF
The coil is OFF, and the timer value and the
contact stay at their present condition
The counting value is back to zero. Both coil and
contact are turned OFF.
The coil is OFF, and the counting value and the
contact stay at their present condition
All turned OFF
Stay at present condition
All of them are not acted , but the nest loop
FOR-NEXT command will still be executed for
times defined by users even though the MC-MCR
commands is OFF.
Operation
X0
Load contact A of
Setting of C2 counter is
K100.