Advertisement

Chapter 12 Description of Parameter SettingsC2000 Series

Speed Mode (PG2)

Settings
Reserved
FOC&TQC Function Control
Settings
Bit#
0
1~10
11
12
13
14
15
 Except Bit=0 set to be used in closed loop, other Bit settings are for open loop.

FOC Bandwidth of Speed Observer

Settings
 Setting speed observer to higher bandwidth could shorten the speed response time but will create
greater noise interference during the speed observation. .

FOC Minimum Stator Frequency

Settings
 This parameter is used to set the minimum level of stator frequency at operation status. This
setting ensures the stability and accuracy of observer and avoid interferences from voltage,
current and motor parameter.
FOC Low-pass Filter Time Constant
Settings
 This parameter sets the low-pass filter time constant of a flux observer at start up. If the motor can
not be activated during the high-speed operation, please lower the setting in this parameter.
0: Electronic Frequency
1: Mechanical Frequency (base on pole pair)
0~65535
Description
ASR control at sensorless torque
0:use PI as ASR; 1:use P as ASR
NA
Activate DC braking when executing zero torque command
0:ON , 1:OFF
FOC Sensorless mode, cross zero means speed goes from negative to
positive or positive to negative (forward to reverse direction or reverse to
forward direction). 0: determine by stator frequency , 1: determine by speed
command
NA
NA
Direction control at open loop status
0: Switch ON direction control 1: Switch OFF direction control
20.0~100.0Hz
0.0~10.0%fN
1~1000ms
168
Factory Setting: 0
Factory Setting: 0
Factory Setting:40.0
Factory Setting:2.0
Factory Setting:50