Stator Resistance Of Pm Motor; Permanent Magnet Motor Ld, Lq; Pg Offset Angle Of Pm Motor; Ke Parameter Of Pm Motor - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Delta Motor (Low inertia model)
Rated Power(kW)
Rotor inertia (kg.m^2)
Delta Motor (Mid to High Inertia model)
Rated Power(kW)
Rotor inertia (kg.m^2)
※ For more information on motor inertia value, please refer to Pr.11-01.

Stator Resistance of PM Motor

Settings
Permanent Magnet Motor Ld
Settings
Permanent Magnet Motor Lq
Settings

PG Offset angle of PM Motor

Settings
 When Pr.05-00 is set to 4, the drive will detect offset angle and write into Pr.05-42.

Ke parameter of PM Motor

Settings
Chapter 12 Description of Parameter SettingsC2000 Series
0.1
0.2
3.70E-06 1.77E-05 2.77E-05 6.80E-05 1.13E-04 2.65E-04 4.45E-04
0.5
1
8.17E-04 8.41E-04 1.12E-03 1.46E-03 3.47E-03 8.17E-04 8.41E-04 1.12E-03
0.000~65.535
0.00~655.35 mH
0.00~655.35 mH
0.0~360.0°
0~65535
12-
0.4
0.4
0.75
1.5
2
2
98
1
2
0.3
0.6
0.9
Factory Setting: 0.000
Factory Setting: 0.00
Factory Setting: 0.00
Factory Setting: 0
Unit: V/1000rpm
Factory Setting: 0