Warning Codes - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Warning
CE01
Comm. Error 1
ID No.
Display on LCM Keypad
1
Warning
Comm. Error 1
2
Warning
Comm. Error 2
3
Warning
Comm. Error 3
4
Warning
Comm. Error 4
5
Warning
Comm. Error 10
6
Warning
Keypad time out
7
Warning
Save Error 1
8
Warning
Save Error 2
9
Warning
Over heat 1 warn
Chapter 13 Warning Codes
Di s p la y e rr o r si g n al
A b b r ev i a te e rr o r c o d e
T h e co d e is d is p l a y e d as s h ow n on K P C- C E 01 .
D i s p la y er r o r d e s c r i p ti o n
CE01
CE02
CE03
CE04
CE10
CP10
SE1
SE2
oH1
Chapter 13 Warning CodesC2000 Series
Descriptions
Modbus function code error
Address of Modbus data is error
Modbus data error
Modbus communication error
Modbus transmission time-out
Keypad transmission time-out
Keypad COPY error 1
Keypad simulation error, including communication delays,
communication error (keypad recived error FF86) and
parameter value error.
Keypad COPY error 2
Keypad simulation done, parameter write error
IGBT over-heating warning