Afm2 Output Bias; Avi & Aci Selection - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

03-22=0
03-25=0
Reserve

AFM2 Output Bias

Settings
Example 1, AFM2 0-10V is set output frequency, the output equation is
Output
Frequency
10V
(
01
Example 2, AFM2 0-20mA is set output frequency, the output equation is
Output
20mA
(
Example 3, AFM2 4-20mA is set output frequency, the output equation is
4mA
16mA
(
AVI Selection
Settings
ACI Selection
Settings
 When changing the input mode, please check if the switch of external terminal (SW3, SW4)
corresponds to the setting of Pr.03-28~03-29.
10V( 20mA)
03-18
03-21
0V
03-24
( 0mA)
Selections for the analog output dir ec ti on
-100.00~100.00%
)
03
-
24
10V
-
00
Frequency
)
03
-
24
01
-
00
Output
Frequency
)
01
-
00
0: 0-10V
1: 0-20mA
2: 4-20mA
0: 4-20mA
1: 0-10V
2: 0-20mA
Chapter 12 Description of Parameter SettingsC2000 Series
10V( 20mA)
F requenc y
0V
( 0mA)
03-22=1
03-25=1
03
-
27
20mA
03
-
27
03
-
24
16mA
03
-
27
12-
79
10V( 20mA)
F requenc y
5V
( 12mA)
03-22=2
03-25=2
Factory Setting: 0.00
Factory Setting: 0
Factory Setting: 0