Delta C2000 series User Manual page 213

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Pr.
Explanation
 10-19
Positioning for Encoder Position
Range for Encoder Position
 10-20
Attained
 10-21
Filter Time (PG2)
10-22
Speed Mode (PG2)
10-23
Reserved
10-24
FOC&TQC Function Control
FOC Bandwidth of
10-25
Speed Observer
10-26
FOC Minimum Stator Frequency
FOC Low-pass Filter Time
10-27
Constant
FOC Excitation Current Rise
10-28
Time
10-29
Top Limit of Frequency Deviation
10-30
Resolver Pole Pair
10-31
I/F Mode, current command
PM Sensorless Obeserver
10-32
Bandwith for High Speed Zone
10-33
Reserved
PM Sensorless Observer
10-34
Low-pass Filter Gain
10-35
Reserved
10-36
Reserved
10-37
PM Sensorless Control Word
10-38
Reserved
Frequency when switch from I/F
10-39
Mode to PM sensorless mode.
Frequency when switch from PM
10-40
sensorless observer mode to
V/F mode.
10-41
I/F mode, low pass-filter time
10-42
Initial Angle Detection Time
10-43
PG card version
Chapter 11 Summary of Parameter SettingsC2000 Series
Settings
0~65535pulse
0~65535pulse
0~65.535 sec
0: Electronic Frequency
1: Mechanical Frequency (base on pole pair)
0~65535
1.0~100.0Hz
0.0~2.0%fN
1~1000ms
33~100%Tr
0.00~100.00Hz
1~50
0~150%Irated (Rated current % of the drive)
0.00~600.00Hz
0.00~655.35 Hz
0000~FFFFh
0.00~600.00Hz
0.00~600.00Hz
0.0~6.0sec
0~20ms
0~655.35
11-33
Factory
Setting
0
10
0.100
0
0
40.0
2.0
50
100
20.00
1
40
5.00
1.00
0000
20.00
20.00
0.2
5
Read
only