Delta C2000 series User Manual page 527

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

API
LN
125
D
P
Bit Devices
X
M
Y
K
S
D
Operands:
Please refer to the specifications of each model for the
range of operands.
Explanation
Example
Word Devices
H
KnX KnY KnM
T
S: Source device D: Operation result
The base is e = 2.71828 and exponent is S
[
[ D +1,D ]=EXP
S +1,S
Only a positive number is valid for S. Register D has to be 32-bit format.
Operation is conducted in floating point value, so the value in S needs to be
converted into floating value before exponent operation.
S
The content in D =e
eD = S. The content of D = LN S, where the value in S is specified by users.
When M0 = ON, convert (D1, D0) to binary floating value and save the
result in (D11, D10).
When M1= ON, perform natural logarithm operation with (D11, D10) as the
antilogarithm. The value is saved in register (D21, D20) in binary floating
format.
Chapter 16 PLC Function C2000 Series
Float Natural Logarithm Operation
16-bit command (5 STEPS)
C
D
32-bit command
DLN
Flag signal: none
]
; e=2.71828 and S is the specified data source
16-80
DLNP