Delta C2000 series User Manual page 368

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Content
Address
2102H Frequency command (F)
2103H Output frequency (H)
2104H Output current (AXX.X.X)
2105H DC-BUS Voltage (UXXX.X)
2106H Output voltage (EXXX.X)
2107H Current step number of Multi-Step Speed Operation
2108H Reserved
2109H Counter value
210AH Power Factor Angle (XXX.X)
210BH Output Torque (%)
210CH Actual motor speed (rpm)
210DH Number of PG feed back pulses
210EH Number of PG2 pulse commands
210FH Power output (X.XXX)
2116H Multi-function display (Pr.00-04)
211BH Max. opeartion frequency (Pr.01-00) or Max. user defined
2200H Display output current (A)
2201H Display counter value (c)
2202H Actual output frequency (H)
2203H DC-BUS voltage (u)
2204H Output voltage
2205H Power angle
2206H Display actual motor speed kW of U, V, W (P)
2207H Display motor speed in rpm estimated by the drive or encoder
2208H Display positive/negative output torque in %, estimated by the
2209H Display PG feedback (as Pr. 00-04 NOTE 1)
220AH PID feedback value after enabling PID function in % (b)
220BH Display signal of AVI analog input terminal, 0-10V corresponds
220CH Display signal of ACI analog input terminal, 4-V20mA/0-10V
220DH Display signal of AUI analog input terminal, -10V~10V
220EH IGBT temperature of drive power module in
220FH The temperature of capacitance in
2210H The status of digital input (ON/OFF), refer to Pr.02-12 (as Pr.
Chapter 12 Description of Parameter SettingsC2000 Series
Bit4~3
Operation Direction
00B: FWD run
01B: From REV run to FWD run
10B: REV run
11B: From FWD run to REV run
Bit8
1:Master frequency controlled by communication
interface
Bit9
1:Master frequency controlled by analog signal
Bit10
1:Operation command controlled by
communication interface
Bit11
1:Parameter locked
Bit12
1:Enable to copy parameters from keypad
Bit15~13 Reserved
value (Pr.00-26)
feedback
drive (t0.0: positive torque, -0.0: negative torque)
to 0-100% (1.) (as Pr. 00-04 NOTE 2)
corresponds to 0-100% (2.) (as Pr. 00-04 NOTE 2)
corresponds to -100~100% (3.) (as Pr. 00-04 NOTE 2)
00-04 NOTE 3)