Chapter 11 Summary of Parameter SettingsC2000 Series
00-41
Homing by frequency 1
00-42
Homing by frequency 2
00-43
~
Reserved
00-47
00-48
Display Filter Time (Current)
00-49
Display Filter Time (Keypad)
00-50
Software Version (date)
00-51
~
Reserved
00-61
5: Forward run and search for Z-pulse as check
point.
6: Forward run to home. Set ORG: ON→OFF
as check point.
7: Reverse run to home. Set ORG : ON→OFF
as check point.
8: Define current position as home.
Set X to 0, 1, 2, 3, 6, 7 first.
0: reverse run to Z pulse
Y
1: continue forward run to Z pulse
2: Ignore Z pulse
When home limit is reached, set X to 2, 3, 4, 5,
6, 7 first.
Z
0: display the error
1: reverse the direction
0.00~600.00Hz
0.00~600.00Hz
0.001~65.535 sec
0.001~65.535 sec
Read only
11-6
8.00
2.00
0.100
0.100
#####