Analog Input Curve Selection; Avi Low/Mid/High Point; Avi Proportional Low/Mid/High Point - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement


Reserve
~

Analog Input Curve Selection

Settings
AVI Low Point
Settings
AVI Proportional Low Point
Settings
AVI Mid Point
Settings
AVI Proportional Mid Point
Settings
AVI High Point
Settings
AVI Proportional High Point
Settings
 When Pr.03-28 = 0, AVI setting is 0-10V and the unit is in voltage (V).
 When Pr.03-28 ≠ 0, AVI setting is 0-20mA or 4-20mA and the unit is in current (mA).
 When setting analog input AVI to frequency command, it 100% corresponds to Fmax (Pr.01-00
Max. operation frequency).
Chapter 12 Description of Parameter SettingsC2000 Series
0: Regular Curve
1: 3 point curve of AVI
2: 3 point curve of ACI
3: 3 point curve of AVI & ACI
4: 3 point curve of AUI
5: 3 point curve of AVI & AUI
6: 3 point curve of ACI & AUI
7: 3 point curve of AVI & ACI & AUI
03-28=0, 0.00~10.00V
03-28≠0, 0.00~20.00mA
0.00~100.00%
03-28=0, 0.00~10.00V
03-28≠0, 0.00~20.00mA
0.00~100.00%
03-28=0, 0.00~10.00V
03-28≠0, 0.00~20.00mA
0.00~100.00%
12-
81
Factory Setting: 0
Factory Setting: 0.00
Factory Setting: 0.00
Factory Setting: 5.00
Factory Setting: 50.00
Factory Setting: 10.00
Factory Setting: 100.00