Delta C2000 series User Manual page 584

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Diagram 2: When Slave 1 on-line status is detected, it will delay for 3 seconds before control
command is enabled.
17
M700
Node 0 online
33
M100
Enable Control
Diagram 3: Commanding Slave 1 to forward run in 30.00Hz for 1 second and reverse run in 60.00Hz
for 1 second and repeats frequency switching.
41
M300
+30.00Hz
52
M301
-60.00Hz
64
M302
Repeat
M100
Enable control
73
M300
+30.00Hz
M301
-60.00Hz
84
T0
Enable Control Delay
T0
Enable Control Delay
M250
Node 0 arrive
M250
Node 0 arrive
T10
M100
Enable control
T11
16-137
Chapter 16 PLC Function C2000 Series
MOVP
Internal node control mode
TMR
MOVP
Internal node control mode
MOV
Reference command of Internal Node 0
TMR
MOV
Reference command of Internal Node 0
TMR
MOV
ROLP
D1121
K0
T0
K30
Enable Control Delay
( M100 )
Enable Control
( M215 )
Reset
K0
D1121
( M207 )
Node 0 Servo On
( M200 )
Node 0 Ack
D1122
K3000
T10
K10
( M200 )
Rev
K6000
D1122
K10
T11
K1
K1M300
+30.00Hz
K4M300
K1
+30.00Hz
END

Advertisement

Table of Contents
loading

Table of Contents