Function Code
Function Code
01
02
03
05
06
0F
10
Only when PLC is at Stop status, PLC data can be read/write via communication device. When PLC
is at Run status, the communication address should be the mapping address, e.g. for Pr.04-00 it
maps to 0400H.
NOTE
When PLC function is activated, C2000 can Read/Write the PLC and drive's parameter by different
addresses (pre-defined station number for the AC motor drive is 1, for PLC station number is 2)
Description
Read coil status
Read input status
Read one data
Force changing one coil status
Write in one data
Force changing multiple coil status
Write in multiple data
16-33
Chapter 16 PLC Function C2000 Series
Supported Devices
Y, M, T, C
X,Y,M,T,C
T,C,D
Y,M,T,C
T,C,D
Y,M,T,C
T,C,D