JOG Frequency

Settings
 Both external terminal JOG and key "F1" on the keypad KPC-CC01 can be used. When the jog
command is ON, the AC motor drive will accelerate from 0Hz to jog frequency (Pr.01-22). When the
jog command is OFF, the AC motor drive will decelerate from Jog Frequency to zero. The Jog
Accel./Decel. time (Pr.01-20, Pr.01-21) is the time that accelerates from 0.0Hz to Pr.01-22 JOG
Frequency.
 The JOG command can't be executed when the AC motor drive is running. In the same way, when
the JOG command is executing, other operation commands are invalid except forward/reverse
commands and STOP key on the digital keypad.
 It does not support JOG function in the optional keypad KPC-CE01.

1st/4th Accel./decel. Frequency

Settings
 The transition from acceleration/deceleration time 1 to acceleration/deceleration time 4, may also be
enabled by the external terminals. The external terminal has priority over Pr. 01-23.
 When using this function, please set S-curve acceleration time as 0 if 4
short.
01-23

S-curve Acceleration Begin Time 1

Frequency
01-00
Max. O utput
Frequency
Frequency
Setting
accel. time
01-12,14,16,18,20
0.00~600.00Hz
0.00~600.00Hz
F reque nc y
1st Acceler ati on
Time
4th A cceleration
Time
1st/4th A cceleration/Dec eleration F requenc y S witchi ng
Chapter 12 Description of Parameter SettingsC2000 Series
decel. time
01-13,15,17,19,21
Accel./Decel. Time
4th Dec eleration
T ime
1s t Dec eleration
12-28
Time
Factory Setting: 6.00
Factory Setting: 0.00
th
acceleration time is set too
T ime
Ti me