Ldf; Andp - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

detection status of the acquired contact rising-edge into the accumulative register.
Example
Ladder diagram:
X0
Please refer to the specification of each model series for the applicable range of
Remarks
operands.
If rising-edge status is ON when PLC power is off, then the rising-edge status will be
TRUE when PLC power is on.
Mnemonic
Falling-edge detection operation

LDF

X0~X17
Operand
Usage of the LDF command is the same as the LD command, but the motion is different. It is
used to reserve present contents and at the same time, saving the detection status of the
acquired contact falling-edge into the accumulative register.
Ladder diagram:
Example
X0
Mnemonic
Rising-edge series connection

ANDP

X0~X17
Operand
ANDP command is used in the series connection of the contacts' rising-edge detection.
Ladder diagram:
Example
X0
X1
Y1
Y0~Y17
M0~M799
X1
Y1
Y0~Y17
M0~M799
X1
Y1
Chapter 16 PLC Function C2000 Series
Command code:
LDP
AND
OUT
Function
T0~159
Command code:
LDF
AND
OUT
Function
T0~159
Command code:
LD
ANDP
OUT
16-43
Operation:
Start X0 rising-edge
X0
detection
Series connection A
X1
contact of X1
Y1
Drive Y1 coil
C0~C79
D0~D399
Operation:
Start X0 falling-edge
X0
detection
Series connection A
X1
contact of X1
Y1
Drive Y1 coil
C0~C79
D0~D399
Operation:
Load A contact of X0
X0
X1 rising-edge
detection in series
X1
connection
Drive Y1 coil
Y1