16.3 Start-up

16.3.1 The Steps for PLC Execution

Please operate PLC functions by following the steps indicate below:
1.
Press menu key on KPC-CC01  select 3: PLC
NOTE
When using KPC-CE01 series digital keypad, switch the mode to PLC2 for program
download/upload:
A. Press MODE key and select 'PLC'.
B. Press 'UP' key and look for 'PLC2' then press 'ENTER'.
C. If succeed, display 'END' for one to two seconds and return to 'PLC2' page.
The PLC warning that is displayed before program downloaded to C2000 can be ignored, please
continue the operation.
2.
Connection: Connect RJ-45 of AC motor drive to the computer by using RS485.
3.
Run the program.
PLC
1.Disable
2.PLC Run
3.PLC Stop
When external input terminals (MI1~MI8) are set to PLC Mode select bit0 (51) or PLC Mode
select bit1 (52), it will force to switch to PLC mode regardless the terminal is ON or OFF.
Meanwhile, switching via keypad is disabled. Please refer to the chart below:
F 60.00Hz
H 0.00Hz
A 0.00Hz
Press
MENU
Disable
RS485
PLC function, select function 2 (PLC Run).
1: Disable
2: PLC Run (PLC1)
3: PLC Stop (PLC2)
Optional accessories: Digital keypad KPC-CE01, display
PLC function as shown in the ( ).
Chapter 16 PLC Function C2000 Series
 ENTER.
MENU
1.Pr Setup
2.Copy Pr
3.PLC
Select 3.PLC
Press
ENTER
PLC Stop
Run PLC
i
AC d i
C2000
(PLC0)
16-5
PLC
1.Disable
2.PLC Run
3.PLC Stop