When the "Register" window appears, click "Transmit".
When transmission window appear, select "read" and input the range D2000~D2799
then press enter. The value in D2000~D2799 will be read. If communication failed,
check the communication format (pre-defined PLC station is 2, 9600, 7N2, ASCII).
Insert the slave station for control. Set D2000 and D2100 to 20 and 21 then set D2200,
D2300, D2400, D2500, D2600 and D2700 to 0.
Click"Transmit" again. When transmission window appears, input the range
D2000~D2799 and enter. The value in D2000~D2799 will be write (If communication
error occur and display failed, it means PLC is not in "stop" status. The value can only
be write in "stop" status, pleas switch PLC to "stop".)
Another method is by setting D1091. Set the corresponding bit of the excluding slave
to 0 (slave station range from No.1~8). For example, if the user wants to exclude slave
No. 2, 6 and 7, please set D1091 = 003B by following steps: WPL Editor >
communication> Edit Register Memory(T C D)
3.
Setup the communication setting. If following conditions apply to you then no additional
setting needs to be done:
If the only control in this application is the speed mode of AC motor drive. (For
other control such as position and torque control, D2000~D2799 should be set. Please
refer to synchronous control on position, torque and zero return for more set up detail.
To perform synchronous control on position for the slave, please enable the
corresponding function PDO 3. (P to P function is not yet supported by C2000.)
To activate PDO 3 TX (Master sending command to Slave), please set up bit
8~11 of the PLC address D2034+n*100. This special D register is defined as
below:
Chapter 16 PLC Function C2000 Series
16-120