Password Decode Flow Chart
Pass word Setting
00-08
Displays 01 after
correct password is
entered to Pr.00-08.
Decode Flow Char t
00-08
Password Set
00-07
Password Input
Pr.00-08=0
No
Re-apply power.
(The password is still valid)
Reserved
Control Mode
Settings
This parameter determines the control mode of C2000 series AC motor drive.
Control of Speed Mode
Settings
This parameter determines the control method of the AC motor drive:
Pass word Forgotten
00-07
Enter 9999 and press ENTER,
then ente r 9999 aga in withi n 10
se cond s an d pre ss ENTER.
Then all pa ra meters will re set
to factory se ttings .
Yes
Shut down th drive
and re-app ly power
0: Speed mode
1: Point-to-Point position control
2: Torque mode
3: Home mode
0: VF (IM V/f control)
1: VFPG (IM V/f control+ Encoder)
2: SVC(IM sensorless vector control)
3: FOCPG (IM FOC vector control+ encoder)
4: FOCPG(PM FOC vector control + Encoder)
5: FOC Sensorless (IM field oriented sensorless vector control)
6 : PM Sensorless (PM field oriented sensorless vector control)
Chapter 12 Description of Parameter SettingsC2000 Series
Pass word Incorrect
3 chan ces of p assword inpu t:
Incorre ct p ass word 1:
Incorre ct p ass word 2:
Incorre ct p ass word 3: "Pcode "(blin king)
Keyp ad will be loc ked after 3 wrong attemp ted
pas swords. To re-activate t he k eypa d, pl ease
reboo t the drive an d in put t he c orrect
pas sword.
12-6
00-07
d ispl ays "01"
disp lays "02 "
Factory Setting: 0