Environment

Noise immunity
Operation/storage
Vibration/shock immunity

Install CMC-MOD01 to VFD-C2000

1.
Switch off the power supply of VFD-C2000.
2.
Open the front cover of VFD-C2000.
3.
Place the insulation spacer into the positioning pin at Slot 1 (shown in Figure 3), and aim the
two holes on the PCB at the positioning pin. Press the pin to clip the holes with the PCB (shown
in Figure 4).
4.
Screw up at torque 6 ~ 8 kg-cm (5.21 ~ 6.94 in-lbs) after the PCB is clipped with the holes
(shown in Figure 5).
ESD (IEC 61800-5-1, IEC 61000-4-2)
EFT (IEC 61800-5-1, IEC 61000-4-4)
Surge Test (IEC 61800-5-1, IEC 61000-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6)
Operation: -10°C ~ 50°C (temperature), 90% (humidity)
Storage: -25°C ~ 70°C (temperature), 95% (humidity)
International standard: IEC 61800-5-1, IEC 60068-2-6/IEC
61800-5-1, IEC 60068-2-27
Slot 3
Slot 2
Slot 1
[Figure 3]
[Figure 5]
8-15
Chapter 8 Optional Cards C2000 Series
[Figure 4]