Analog Input Terminals (Avi, Aci, Aui, Acm); Digital Inputs (Fwd, Rev, Mi1~Mi8, Com); Transistor Outputs (Mo1, Mo2, Mcm) - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Terminals
Terminal Function
AFM2
ACM
Analog Signal Common
S1
Power removal safety function for EN954-1 and IEC/EN61508
SCM
SG+
SG-
Modbus RS-485
SGND
PIN 1,2,7,8 :Reserved
RJ-45
PIN 4: SG-

6-2 Analog input terminals (AVI, ACI, AUI, ACM)

Analog input signals are easily affected by external noise. Use shielded wiring and keep it as
short as possible (<20m) with proper grounding. If the noise is inductive, connecting the shield to
terminal ACM can bring improvement.
If the analog input signals are affected by noise from the AC motor drive, please connect a
capacitor and ferrite core as indicated in the following diagram.

Digital inputs (FWD, REV, MI1~MI8, COM)

When using contacts or switches to control the digital inputs, please use high quality components
to avoid contact bounce.

Transistor outputs (MO1, MO2, MCM)

 Make sure to connect the digital outputs to the right polarity.
When connecting a relay to the digital outputs connect a surge absorber across the coil and
check the polarity.
frequency
Range: 0~10V  -10~+10V
AFM 1 Switch, factory setting is 0~10V
0~10V
0~20mA
Output current: 20mA max
Resolution: 0~10V corresponds to Max. operation
frequency
Range: 0~10V  0/4~20mA
AFM 2 Switch, factory setting is 0~10V
Common for analog terminals
PIN 3, 6: SGND
PIN 5: SG+
NOTE: Wire size of analog control signals: 18 AWG (0.75 mm
C
ferrite core
Wind each wires 3 times or more around the core
Chapter 6 Control TerminalsC2000 Series
Factory Setting (NPN mode)
Max.
output current 2mA,
Max.
load 500Ω
AVI/ACI/AUI
AC M
6-5
Max.
load 5kΩ
2
) with shielded wire

Advertisement

Table of Contents
loading

Table of Contents