API
CANFLS
265
P
Bit Devices
X
Y
M
K
D
Operands: None
1.
D: the special D for update.
Explanation
2.
CANFLS can update the Special D command. When it executes in read only
mode, it sends equivalent message as CANRX to the slave and saves the slave
response to this particular Special D. When it executes in read/write mode, it
sends equivalent message as CANTX to the slave and saves this special D
value to the corresponding slave.
3.
M1066 and M1067 are both 0. When reading is complete, M1066 will be 1 and
this value will write to the designated register if the slave replies an accurate
response. When slave replies a fault response then M1067 will be 0 and this
error message will be recorded to D1076~D1079.
API
ICOMR
320
D
P
Bit Devices
X
Y
M
K
S1
S2
S3
D
Operands: None
S1
slave station number
Explanation
S3
: Reading address
D
: Saving device
The ICOMR command can read the register of the AC motor drive and that of
internal PLC from slave station.
D
Word Devices
H KnX KnY KnM T
D
Word Devices
H
KnX KnY KnM
T
S2
:Device chosen (0: AC motor drive 1: Internal PLC)。
16-116
Chapter 16 PLC Function C2000 Series
Update the mapping special D of CANopen
16-bit command (7 STEPS)
FREQ
C
D
32-bit command
Flag signal: M1028
Internal Communication Reader
16-bit command (7 STEPS)
ICOMR
continuous
C
D
processing
32-bit command
Flag signal: M1077 M1078 M1079
FREQP
ICOMRP
pulse
processing