Delta C2000 series User Manual page 442

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Display
Fault code
Fault
oL
Inverter oL
Fault
Fault
EoL1
EoL2
Thermal relay 2
Thermal relay 1
Fault
EoL2
Thermal relay 2
Fault
Fault
EoL2
ot1
Over torque 1
Thermal relay 2
Fault
Fault
EoL2
ot2
Over torque 2
Thermal relay 2
Fault
Fault
EoL2
uC
Thermal relay 2
Under torque 1
Fault
Fault
EoL2
cF1
Thermal relay 2
EEPROM write Err
Fault
Fault
EoL2
cF2
Thermal relay 2
EEPROM read Err
Fault
Fault
EoL2
cd1
Thermal relay 2
Ias sensor Err
Fault
Fault
EoL2
cd2
Thermal relay 2
Ibs sensor Err
Fault
Fault
cd3
EoL2
Thermal relay 2
Ics sensor Err
Overload. The AC motor drive detects
excessive drive output current.
0015H
NOTE: The AC motor drive can withstand up to
150% of the rated current for a maximum of 60
seconds.
0016H
Electronics thermal relay 1 protection
0017H
Electronics thermal relay 2 protection
These two fault codes will be displayed
001AH
when output current exceeds the
over-torque detection level (Pr.06.07 or
Pr.06.10) and exceeds over-torque
detection (Pr.06.08 or Pr.06.11) and it is
001BH
set 2 or 4 in Pr.06-06 or Pr.06-09.
001CH
Low current
Internal EEPROM can not be
001EH
programmed.
001FH
Internal EEPROM can not be read.
0021H
U-phase error
0022H
V-phase error
0023H
W-phase error
15-29
Chapter 15 CANopen Overview C2000 Series
Description
CANopen
CANopen
fault
fault code
register
(bit 0~7)
2310H
1
2310H
1
2310H
1
8311H
3
8311H
3
8321H
1
5530H
5
5530H
5
FF04H
1
FF05H
1
FF06H
1

Advertisement

Table of Contents
loading

Table of Contents