Chapter 11 Summary of Parameter SettingsC2000 Series
Pr.
Explanation
06-63
Fault Record 1 (Day)
06-64
Fault Record 1 (Min)
06-65
Fault Record 2 (Day)
06-66
Fault Record 2 (Min)
06-67
Fault Record 3 (Day)
06-68
Fault Record 3 (Min)
06-69
Fault Record 4 (Day)
06-70
Fault Record 4 (Min)
06-71
Low Current Setting Level
06-72
Low Current Detection Time
06-73
Treatment for low current
Settings
0~65535 days
0~1439 min
0~65535 days
0~1439 min
0~65535 days
0~1439 min
0~65535 days
0~1439 min
0.0 ~ 6553.5 %
0.00 ~ 655.35sec
0 : No function
1 : Warn and coast to stop
2 : Warn and ramp to stop by 2nd deceleration time
3 : Warn and operation continue
11-24
Factory
Setting
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
0.0
0.00
0