OSPF C
OMMANDS
-
IP OSPF HELLO
INTERVAL

ip ospf hello-interval

Overview
This command specifies the interval between hello packets.
The hello-interval is advertised in the hello packets. Configure the same
hello-interval for all routers on a specific network. A shorter hello interval ensures
faster detection of topological changes, but results in more routing traffic.
The no variant of this command returns the interval to the default of 10 seconds.
ip ospf [<ip-address>] hello-interval <1-65535>
Syntax
no ip ospf [<ip-address>] hello-interval
Default
The default interval is 10 seconds.
Mode
Interface Configuration for a VLAN interface.
Example
The following example shows setting the hello-interval to 3 seconds on VLAN
interface vlan2.
awplus#
awplus(config)#
awplus(config-if)#
Related
ip ospf dead-interval
Commands
show ip ospf interface
C613-50170-01 Rev B
Parameter
Description
<ip-address> The IP address of the interface, in dotted decimal notation.
<1-65535>
The interval in seconds.
Default: 10
configure terminal
interface vlan2
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
ip ospf hello-interval 3