Configuration Guide - Reliability
Configure the link aggregation group in 1:1 active/standby mode on Router A and Router B.
Configure Ethernet CFM on Router A, Router B, Router C, and Router D respectively. Associate
Ethernet CFM with GE 1/0/1 and GE 1/0/2 on Router A and Router B.
Assume that a connectivity fault occurs on the link between Router A and Router C. The Ethernet
CFM module detects the fault and notifies the OAM management module of the fault. The OAM
management module shuts down and then starts GE 1/0/1. This allows the link aggregation group
to sense the fault and switch the service data to the inactive link. The procedure for processing
connectivity faults on the other links is similar to that for processing the link fault between Router
A and Router C. This implements protection switching in no more than 50 ms to achieve carrier-
class reliability.
Pre-configuration Tasks
Before associating Ethernet CFM with an interface, complete the following tasks:
l
l
Data Preparation
To associate Ethernet CFM with an interface, you need the following data.
No.
1
2
Associating Ethernet CFM with an Interface
Through the configured association between Ethernet CFM and an interface, a MEP in a
specified MA can detect a connectivity fault between the MEP and a specified RMEP within
the same MA. Then, the OAM module blocks and then unblocks the interface on which the MEP
resides so that other modules can sense the fault.
Context
Perform the following steps on the NE80E/40E configured with the link aggregation group in
static LACP mode:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
Issue 02 (2014-09-30)
Configure the link aggregation group.
Configure Ethernet CFM.
Data
Type and number of an interface
Name of an MD, MA, and ID of an RMEP
Huawei Proprietary and Confidential