continue the test and send test packets at a lower rate. The bisection method is used to send test
packets at different rates between the upper and lower rate thresholds. The test process repeats
until a maximum bandwidth is found when no packets are dropped in a test. In addition, check
for bit errors on MEP2 that receives test packets.
Figure 8-61 ETH-test function for a VLAN network
Procedure
Step 1 Perform the following steps on PEs:
1.
2.
3.
4.
5.
6.
7.
8.
Issue 02 (2014-09-30)
CE1
PE1
MEP1
Run:
system-view
The system view is displayed.
Run:
cfm enable
CFM is enabled globally.
By default, CFM is disabled globally.
Run:
cfm md md-name
The MD view is displayed.
Run:
ma ma-name
The MA view is displayed.
Run:
map vlan vlan-id
The MA is associated with a VLAN.
Run:
mep mep-id
A MEP is configured.
Run:
eth-test enable
The ETH-test function is enabled.
By default, the ETH-test function is disabled.
Run:
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
VLAN
ETH-TEST
8 Ethernet OAM Configuration
PE2
CE2
MEP2